new

Get trending papers in your email inbox!

Subscribe

Daily Papers

byAK and the research community

Jul 23

PitVis-2023 Challenge: Workflow Recognition in videos of Endoscopic Pituitary Surgery

The field of computer vision applied to videos of minimally invasive surgery is ever-growing. Workflow recognition pertains to the automated recognition of various aspects of a surgery: including which surgical steps are performed; and which surgical instruments are used. This information can later be used to assist clinicians when learning the surgery; during live surgery; and when writing operation notes. The Pituitary Vision (PitVis) 2023 Challenge tasks the community to step and instrument recognition in videos of endoscopic pituitary surgery. This is a unique task when compared to other minimally invasive surgeries due to the smaller working space, which limits and distorts vision; and higher frequency of instrument and step switching, which requires more precise model predictions. Participants were provided with 25-videos, with results presented at the MICCAI-2023 conference as part of the Endoscopic Vision 2023 Challenge in Vancouver, Canada, on 08-Oct-2023. There were 18-submissions from 9-teams across 6-countries, using a variety of deep learning models. A commonality between the top performing models was incorporating spatio-temporal and multi-task methods, with greater than 50% and 10% macro-F1-score improvement over purely spacial single-task models in step and instrument recognition respectively. The PitVis-2023 Challenge therefore demonstrates state-of-the-art computer vision models in minimally invasive surgery are transferable to a new dataset, with surgery specific techniques used to enhance performance, progressing the field further. Benchmark results are provided in the paper, and the dataset is publicly available at: https://doi.org/10.5522/04/26531686.

  • 32 authors
·
Sep 2, 2024

CATO: Charted Attention for Neural PDE Operators

Neural operators have emerged as powerful data-driven solvers for PDEs, offering substantial acceleration over classical numerical methods. However, existing transformer-based operators still face critical challenges when modeling PDEs on complex geometries: directly processing over massive mesh points is computationally expensive, while operating in raw discretization coordinates may obscure the intrinsic geometry where physical interactions are more naturally expressed. To address these limitations, we introduce the Charted Axial Transformer Operator (CATO), a geometry-adaptive and derivative-aware neural operator for PDEs on general geometries. Instead of applying attention directly in the physical coordinate system, CATO learns a continuous latent chart that maps mesh coordinates into a learned chart space, where chart-conditioned axial attention efficiently captures long-range dependencies with reduced computational cost. In addition, CATO introduces a derivative-aware physics loss for steady-state PDEs that jointly supervises solution values, mesh-consistent gradients, and an auxiliary flux-like field, improving physical fidelity and reducing oversmoothing. We further provide a theoretical approximation result showing that, under a favorable chart, charted axial attention can represent low-rank axial solution operators with controlled error, and that small chart perturbations induce bounded approximation degradation. CATO achieves the best performance across all evaluated datasets, yielding an average improvement of approximately 26.76\% over the strongest competing baselines while reducing the number of parameters by 81.98\%. These results highlight the effectiveness of learning geometry-adaptive charts and derivative-aware physical supervision for accurate and efficient PDE operator learning.

  • 4 authors
·
May 8

Liver Segmentation using Turbolift Learning for CT and Cone-beam C-arm Perfusion Imaging

Model-based reconstruction employing the time separation technique (TST) was found to improve dynamic perfusion imaging of the liver using C-arm cone-beam computed tomography (CBCT). To apply TST using prior knowledge extracted from CT perfusion data, the liver should be accurately segmented from the CT scans. Reconstructions of primary and model-based CBCT data need to be segmented for proper visualisation and interpretation of perfusion maps. This research proposes Turbolift learning, which trains a modified version of the multi-scale Attention UNet on different liver segmentation tasks serially, following the order of the trainings CT, CBCT, CBCT TST - making the previous trainings act as pre-training stages for the subsequent ones - addressing the problem of limited number of datasets for training. For the final task of liver segmentation from CBCT TST, the proposed method achieved an overall Dice scores of 0.874pm0.031 and 0.905pm0.007 in 6-fold and 4-fold cross-validation experiments, respectively - securing statistically significant improvements over the model, which was trained only for that task. Experiments revealed that Turbolift not only improves the overall performance of the model but also makes it robust against artefacts originating from the embolisation materials and truncation artefacts. Additionally, in-depth analyses confirmed the order of the segmentation tasks. This paper shows the potential of segmenting the liver from CT, CBCT, and CBCT TST, learning from the available limited training data, which can possibly be used in the future for the visualisation and evaluation of the perfusion maps for the treatment evaluation of liver diseases.

  • 12 authors
·
Jul 20, 2022

The Simons Observatory: Cryogenic Half Wave Plate Rotation Mechanism for the Small Aperture Telescopes

We present the requirements, design and evaluation of the cryogenic continuously rotating half-wave plate (CHWP) for the Simons Observatory (SO). SO is a cosmic microwave background (CMB) polarization experiment at Parque Astron\'{o}mico Atacama in northern Chile that covers a wide range of angular scales using both small (0.42 m) and large (6 m) aperture telescopes. In particular, the small aperture telescopes (SATs) focus on large angular scales for primordial B-mode polarization. To this end, the SATs employ a CHWP to modulate the polarization of the incident light at 8 Hz, suppressing atmospheric 1/f noise and mitigating systematic uncertainties that would otherwise arise due to the differential response of detectors sensitive to orthogonal polarizations. The CHWP consists of a 505 mm diameter achromatic sapphire HWP and a cryogenic rotation mechanism, both of which are cooled down to sim50 K to reduce detector thermal loading. Under normal operation the HWP is suspended by a superconducting magnetic bearing and rotates with a constant 2 Hz frequency, controlled by an electromagnetic synchronous motor. We find that the number of superconductors and magnets that make up the superconducting magnetic bearing are important design parameters, especially for the rotation mechanism's vibration performance. The rotation angle is detected through an angular encoder with a noise level of 0.07 muradmathrm{s}. During a cooldown, the rotor is held in place by a grip-and-release mechanism that serves as both an alignment device and a thermal path. In this paper we provide an overview of the SO SAT CHWP: its requirements, hardware design, and laboratory performance.

  • 27 authors
·
Sep 26, 2023

GhostSR: Learning Ghost Features for Efficient Image Super-Resolution

Modern single image super-resolution (SISR) system based on convolutional neural networks (CNNs) achieves fancy performance while requires huge computational costs. The problem on feature redundancy is well studied in visual recognition task, but rarely discussed in SISR. Based on the observation that many features in SISR models are also similar to each other, we propose to use shift operation to generate the redundant features (i.e., ghost features). Compared with depth-wise convolution which is time-consuming on GPU-like devices, shift operation can bring a practical inference acceleration for CNNs on common hardwares. We analyze the benefits of shift operation on SISR task and make the shift orientation learnable based on Gumbel-Softmax trick. Besides, a clustering procedure is explored based on pre-trained models to identify the intrinsic filters for generating intrinsic features. The ghost features will be derived by moving these intrinsic features along a specific orientation. Finally, the complete output features are constructed by concatenating the intrinsic and ghost features together. Extensive experiments on several benchmark models and datasets demonstrate that both the non-compact and lightweight SISR models embedded with the proposed method can achieve a comparable performance to that of their baselines with a large reduction of parameters, FLOPs and GPU inference latency. For instance, we reduce the parameters by 46%, FLOPs by 46% and GPU inference latency by 42% of times2 EDSR network with basically lossless performance.

  • 5 authors
·
Jan 21, 2021

Robotic Ultrasound Makes CBCT Alive

Intraoperative Cone Beam Computed Tomography (CBCT) provides a reliable 3D anatomical context essential for interventional planning. However, its static nature fails to provide continuous monitoring of soft-tissue deformations induced by respiration, probe pressure, and surgical manipulation, leading to navigation discrepancies. We propose a deformation-aware CBCT updating framework that leverages robotic ultrasound as a dynamic proxy to infer tissue motion and update static CBCT slices in real time. Starting from calibration-initialized alignment with linear correlation of linear combination (LC2)-based rigid refinement, our method establishes accurate multimodal correspondence. To capture intraoperative dynamics, we introduce the ultrasound correlation UNet (USCorUNet), a lightweight network trained with optical flow-guided supervision to learn deformation-aware correlation representations, enabling accurate, real-time dense deformation field estimation from ultrasound streams. The inferred deformation is spatially regularized and transferred to the CBCT reference to produce deformation-consistent visualizations without repeated radiation exposure. We validate the proposed approach through deformation estimation and ultrasound-guided CBCT updating experiments. Results demonstrate real-time end-to-end CBCT slice updating and physically plausible deformation estimation, enabling dynamic refinement of static CBCT guidance during robotic ultrasound-assisted interventions. The source code is publicly available at https://github.com/anonymous-codebase/us-cbct-demo.

  • 5 authors
·
Mar 9

The Cylindrical Representation Hypothesis for Language Model Steering

Steering is a widely used technique for controlling large language models, yet its effects are often unstable and hard to predict. Existing theoretical accounts are largely based on the Linear Representation Hypothesis (LRH). While LRH assumes that concepts can be orthogonalized for lossless control, this idealized mapping fails in real representations and cannot account for the observed unpredictability of steering. By relaxing LRH's orthogonality assumption while preserving linear representations, we show that overlapping concept contributions naturally yield a sample-specific axis-orthogonal structure. We formalize this as the Cylindrical Representation Hypothesis (CRH). In CRH, a central axis captures the main difference between concept absence and presence and drives concept generation. A surrounding normal plane controls steering sensitivity by determining how easily the axis can activate the target concept. Within this plane, only specific sensitive sectors strongly facilitate concept activation, while other sectors can suppress or delay it. While the surrounding normal plane can be reliably identified from difference vectors, the sensitive sector cannot, introducing intrinsic uncertainty at the sector level. This uncertainty provides a principled explanation for why steering outcomes often fluctuate even when using well-aligned directions. Our experiments verify the existence of the cylindrical structure and demonstrate that CRH provides a valid and practical way to interpret model steering behavior in real settings: https://github.com/mbzuai-nlp/CRH.

  • 10 authors
·
May 2

Global displacement induced by rigid motion simulation during MRI acquisition

Purpose: Simulation of motion in the frequency domain during the MRI acquisition process is an important tool to study the effect of object motion. It is natural in this context to rely on a voxel-to-voxel difference metric between the original image and its motion-simulated version to quantify the alteration. These metrics are very sensitive to any mis-coregistration between the two images. As we observed global displacements of the corrupted image for specific simulated motions, we focused this work on the critical choice of a reference position of the object for the motion simulation that avoids any global displacement. Methods: We used the motion simulation framework and we studied the different proposed solutions. Classically, the position around the k-space center is considered as a reference with two analytical solutions to correct for global image shifts: demeaning the image in the Fourier domain either using the exact position at k-space center or using a weighted average around the center. Results: We demonstrated with motion simulated examples that these analytical solutions did not yield the same results as a direct co-registration method. Indeed, short transitions around the k-space center did not induce any global displacement, in contrast with what both analytical solutions assumed. We also observed a dependence of the global shift to both the motion amplitude and the translation direction. Conclusion: In the absence of a theoretical solution, we concluded that an extra co-registration step after motion simulation was needed in order to compare the simulation with its reference image.

  • 4 authors
·
Apr 6, 2022